 FUJITSU SEMICONDUCTOR DATA SHEET
DS05-20844-4E
FLASH MEMORY
CMOS
16M (2M x 8) BIT
MBM29F016A-70/-90/-12
s FEATURES
* Single 5.0 V read, write, and erase Minimizes system level power requirements * Compatible with JEDEC-standard commands Pinout and software compatible with single-power supply Flash Superior inadvertent write protection * 48-pin TSOP(I) (Package Suffix: PFTN-Normal Bend Type, PFTR-Reverse Bend Type) * Minimum 100,000 write/erase cycles * High performance 70 ns maximum access time * Sector erase architecture Uniform sectors of 64 K bytes each Any combination of sectors can be erased. Also supports full chip erase. * Embedded EraseTM Algorithms Automatically pre-programs and erases the chip or any sector * Embedded ProgramTM Algorithms Automatically programs and verifies data at specified address * Data Polling and Toggle Bit feature for detection of program or erase cycle completion * Ready/Busy output (RY/BY) Hardware method for detection of program or erase cycle completion * Low VCC write inhibit 3.2 V * Hardware RESET pin Resets internal state machine to the read mode * Erase Suspend/Resume Supports reading or programming data to a sector not being erased * Sector group protection Hardware method that disables any combination of sector groups from write or erase operation (a sector group consists of 4 adjacent sectors of 64 K bytes each) * Temporary sector groups unprotection Temporary sector unprotection via the RESET pin
Embedded EraseTM, Embedded ProgramTM and ExpressFlashTM are trademarks of Advanced Micro Devices, Inc.
MBM29F016A-70/-90/-12
s PACKAGE
48-pin Plastic TSOP(I) Marking Side 48-pin Plastic TSOP(I)
Marking Side (FPT-48P-M19) (FPT-48P-M20)
2
MBM29F016A-70/-90/-12
s GENERAL DESCRIPTION
The MBM29F016A is a 16 M-bit, 5.0 V-Only Flash memory organized as 2 M bytes of 8 bits each. The 2 M bytes of data is divided into 32 sectors of 64 K bytes for flexible erase capability. The 8 bit of data will appear on DQ0 to DQ7. The MBM29F016A is offered in a 48-pin TSOP(I) package. This device is designed to be programmed in-system with the standard system 5.0 V VCC supply. A 12.0 V VPP is not required for program or erase operations. The device can also be reprogrammed in standard EPROM programmers. The standard MBM29F016A offers access times between 70 ns and 120 ns allowing operation of high-speed microprocessors without wait states. To eliminate bus contention the device has separate chip enable (CE), write enable (WE), and output enable (OE) controls. The MBM29F016A is command set compatible with JEDEC standard E2PROMs. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state-machine which controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the device is similar to reading from 12.0 V Flash or EPROM devices. The MBM29F016A is programmed by executing the program command sequence. This will invoke the Embedded Program Algorithm which is an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Each sector can be programmed and verified in less than 0.5 seconds. Erase is accomplished by executing the erase command sequence. This will invoke the Embedded Erase Algorithm which is an internal algorithm that automatically preprograms the array if it is not already programmed before executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin. This device also features a sector erase architecture. The sector erase mode allows for sectors of memory to be erased and reprogrammed without affecting other sectors. A sector is typically erased and verified within 1 second (if already completely preprogrammed). The MBM29F016A is erased when shipped from the factory. The MBM29F016A device also features hardware sector group protection. This feature will disable both program and erase operations in any combination of eight sector groups of memory. A sector group consists of four adjacent sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31. Fujitsu has implemented an Erase Suspend feature that enables the user to put erase on hold for any period of time to read data from or program data to a non-busy sector. Thus, true background erase can be achieved. The device features single 5.0 V power supply operation for both read and program functions. Internally generated and regulated voltages are provided for the program and erase operations. A low VCC detector automatically inhibits write operations during power transitions. The end of program or erase is detected by Data Polling of DQ7, or by the Toggle Bit I feature on DQ6 or RY/BY output pin. Once the end of a program or erase cycle has been completed, the device automatically resets to the read mode. The MBM29F016A also has a hardware RESET pin. When this pin is driven low, execution of any Embedded Program or Embedded Erase operations will be terminated. The internal state machine will then be reset into the read mode. The RESET pin may be tied to the system reset circuity. Therefore, if a system reset occurs during the Embedded Program or Embedded Erase operation, the device will be automatically reset to a read mode. This will enable the system microprocessor to read the boot-up firmware from the Flash memory. Fujitsu's Flash technology combines years of EPROM and E2PROM experience to produce the highest levels of quality, reliability, and cost effectiveness. The MBM29F016A memory electrically erases all bits within a sector simultaneously via Fowler-Nordheim tunneling. The bytes are programmed one byte at a time using the EPROM programming mechanism of hot electron injection.
3
MBM29F016A-70/-90/-12
s FLEXIBLE SECTOR-ERASE ARCHITECTURE
* Thirty two 64 K byte sectors * 8 sector groups each of which consists of 4 adjacent sectors in the following pattern; sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31 * Individual-sector or multiple-sector erase capability * Sector group protection is user-definable 1FFFFFH 64 K byte SA31 1EFFFFH 64 K byte SA30 Sector 1DFFFFH Group 7 64 K byte SA29 1CFFFFH 64 K byte SA28 1BFFFFH 1AFFFFH 19FFFFH 18FFFFH 17FFFFH 16FFFFH 15FFFFH 14FFFFH 13FFFFH 12FFFFH 11FFFFH 10FFFFH 32 Sectors Total 0FFFFFH 0EFFFFH 0DFFFFH 0CFFFFH 0BFFFFH 0AFFFFH 09FFFFH 08FFFFH 07FFFFH 06FFFFH 05FFFFH 04FFFFH SA3 SA2 SA1 SA0 4 64 K byte 64 K byte 64 K byte 64 K byte 03FFFFH 02FFFFH 01FFFFH 00FFFFH 000000H Sector Group 0
MBM29F016A-70/-90/-12
s PRODUCT LINE UP
Part No. VCC = 5.0 V 5% Ordering Part No. VCC = 5.0 V 10% Max. Address Access Time (ns) Max. CE Access Time (ns) Max. OE Access Time (ns) -- 70 70 40 -90 90 90 40 -12 120 120 50 -70 MBM29F016A -- --
s BLOCK DIAGRAM
DQ0 to DQ7 VCC VSS RY/BY Buffer
RY/BY Erase Voltage Generator Input/Output Buffers
WE
State Control
RESET Command Register Program Voltage Generator
CE OE
Chip Enable Output Enable Logic
STB
Data Latch
STB
Y-Decoder
Y-Gating
Low VCC Detector
Timer for Program/Erase
Address Latch
X-Decoder
Cell Matrix
A0 to A20
5
MBM29F016A-70/-90/-12
s CONNECTION DIAGRAMS
TSOP(I) N.C. N.C. A19 A18 A17 A16 A15 A14 A13 A12 CE VCC N.C. RESET A11 A10 A9 A8 A7 A6 A5 A4 N.C. N.C. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 N.C. N.C. A20 N.C. WE OE RY/BY DQ7 DQ6 DQ5 DQ4 VCC VSS VSS DQ3 DQ2 DQ1 DQ0 A0 A1 A2 A3 N.C. N.C.
(Marking Side)
MBM29F016A Standard Pinout
FPT-48P-M19
N.C. N.C. A4 A5 A6 A7 A8 A9 A10 A11 RESET N.C. VCC CE A12 A13 A14 A15 A16 A17 A18 A19 N.C. N.C.
24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(Marking Side)
MBM29F016A Reverse Pinout
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
N.C. N.C. A3 A2 A1 A0 DQ0 DQ1 DQ2 DQ3 VSS VSS VCC DQ4 DQ5 DQ6 DQ7 RY/BY OE WE N.C. A20 N.C. N.C.
FPT-48P-M20
6
MBM29F016A-70/-90/-12
s LOGIC SYMBOL
Table 1 Pin
21 A 0 to A 20 DQ0 to DQ7 8
MBM29F016A Pin Configuration Function Address Inputs Data Inputs/Outputs Chip Enable Output Enable Write Enable Ready/Busy Output Hardware Reset Pin/Sector Protection Unlock No Internal Connection Device Ground Device Power Supply
A0 to A20 DQ0 to DQ7 CE
CE OE WE RESET RY/BY
OE WE RY/BY RESET N.C. VSS VCC Table 2
MBM29F016A User Bus Operations CE L L L H L L L L X X OE L L L X H H VID L X X H X X WE H H H X H L A0 L H A0 X X A0 X L X X A1 L L A1 X X A1 X H X X A6 L L A6 X X A6 X L X X A9 VID VID A9 X X A9 VID VID X X DQ0 to DQ7 RESET Code Code DOUT HIGH-Z HIGH-Z DIN X Code X HIGH-Z H H H H H H H H VID L
Operation Auto-Select Manufacturer Code (1) Auto-Select Device Code (1) Read (3) Standby Output Disable Write (Program/Erase) Enable Sector Group Protection (2) Verify Sector Group Protection (2) Temporary Sector Group Unprotection Reset (Hardware) Legend: L = VIL, H = VIH, X = VIL or VIH,
= Pulse Input. See DC Characteristics for voltage levels.
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. Refer to Table 6. 2. Refer to the section on Sector Group Protection. 3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations.
7
MBM29F016A-70/-90/-12
s ORDERING INFORMATION Standard Products
Fujitsu standard products are available in several packages. The order number is formed by a combination of:
MBM29F016
A
-70
PFTN
PACKAGE TYPE PFTN = 48-Pin Thin Small Outline Package (TSOP) Standard Pinout PFTR = 48-Pin Thin Small Outline Package (TSOP) Reverse Pinout
SPEED OPTION See Product Selector Guide A = Device Revision
DEVICE NUMBER/DESCRIPTION MBM29F016 16 Mega-bit (2 M x 8-Bit) CMOS Flash Memory 5.0 V-only Read, Write, and Erase 64 K Byte (32 Sectors)
8
MBM29F016A-70/-90/-12
s FUNCTIONAL DESCRIPTION Read Mode
The MBM29F016A has two control functions which must be satisfied in order to obtain data at the outputs. CE is the power control and should be used for a device selection. OE is the output control and should be used to gate data to the output pins if a device is selected. Address access time (tACC) is equal to the delay from stable addresses to valid output data. The chip enable access time (tCE) is the delay from stable addresses and stable CE to valid data at the output pins. The output enable access time is the delay from the falling edge of OE to valid data at the output pins (assuming the addresses have been stable for at least tACC-tOE time).
Standby Mode
There are two ways to implement the standby mode on the MBM29F016A device, one using both the CE and RESET pins; the other via the RESET pin only. When using both pins, a CMOS standby mode is achieved with CE and RESET inputs both held at VCC 0.3 V. Under this condition the current consumed is less than 5 A. A TTL standby mode is achieved with CE and RESET pins held at VIH. Under this condition the current is reduced to approximately 1 mA. During Embedded Algorithm operation, VCC Active current (ICC2) is required even CE = VIH. The device can be read with standard access time (tCE) from either of these standby modes. When using the RESET pin only, a CMOS standby mode is achieved with RESET input held at VSS 0.3 V (CE = "H" or "L"). Under this condition the current consumed is less than 5 A. A TTL standby mode is achieved with RESET pin held at VIL (CE = "H" or "L"). Under this condition the current required is reduced to approximately 1 mA. Once the RESET pin is taken high, the device requires 500 ns of wake up time before outputs are valid for read access. In the standby mode the outputs are in the high impedance state, independent of the OE input.
Output Disable
With the OE input at a logic high level (VIH), output from the device is disabled. This will cause the output pins to be in a high impedance state.
Autoselect
The autoselect mode allows the reading out of a binary code from the device and will identify its manufacturer and type. This mode is intended for use by programming equipment for the purpose of automatically matching the device to be programmed with its corresponding programming algorithm. This mode is functional over the entire temperature range of the device. To activate this mode, the programming equipment must force VID (11.5 V to 12.5 V) on address pin A9. Two identifier bytes may then be sequenced from the device outputs by toggling address A0 from VIL to VIH. All addresses are don't cares except A0, A1, and A6. (See Table 3.) The manufacturer and device codes may also be read via the command register, for instances when the MBM29F016A is erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Table 6. (Refer to Autoselect Command section.) Byte 0 (A0 = VIL) represents the manufacturer's code (Fujitsu = 04H) and byte 1 (A0 = VIH) represents the device identifier code for MBM29F016A = ADH. These two bytes are given in the table 3. All identifiers for manufactures and device will exhibit odd parity with DQ7 defined as the parity bit. In order to read the proper device codes when executing the Autoselect, A1 must be VIL. (See Table 3.) The Autoselect mode also facilitates the determination of sector group protection in the system. By performing a read operation at the address location XX02H with the higher order address bits A18, A19 and A20 set to the desired sector group address, the device will return 01H for a protected sector group and 00H for a non-protected sector group. 9
MBM29F016A-70/-90/-12
Table 3 Type Manufacture's Code Device Code Sector Group Protection X X MBM29F016A Sector Protection Verify Autoselect Codes A6 X X VIL VIL VIL A1 VIL VIL VIH A0 VIL VIH VIL Code (HEX) DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 04H ADH 01H* 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0 1 1 0 0 0 0 0 1 1
A18 to A20 X X
Sector Group Addresses
* : Outputs 01H at protected sector addresses and outputs 00H at unprotected sector addresses. Table 4 SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 SA8 SA9 SA10 SA11 SA12 SA13 SA14 SA15 SA16 SA17 SA18 SA19 SA20 SA21 SA22 SA23 SA24 SA25 SA26 SA27 SA28 SA29 SA30 SA31 10 A20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 A19 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 Sector Address Table A18 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 A17 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 A16 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Address Range 000000H to 00FFFFH 010000H to 01FFFFH 020000H to 02FFFFH 030000H to 03FFFFH 040000H to 04FFFFH 050000H to 05FFFFH 060000H to 06FFFFH 070000H to 07FFFFH 080000H to 08FFFFH 090000H to 09FFFFH 0A0000H to 0AFFFFH 0B0000H to 0BFFFFH 0C0000H to 0CFFFFH 0D0000H to 0DFFFFH 0E0000H to 0EFFFFH 0F0000H to 0FFFFFH 100000H to 10FFFFH 110000H to 11FFFFH 120000H to 12FFFFH 130000H to 13FFFFH 140000H to 14FFFFH 150000H to 15FFFFH 160000H to 16FFFFH 170000H to 17FFFFH 180000H to 18FFFFH 190000H to 19FFFFH 1A0000H to 1AFFFFH 1B0000H to 1BFFFFH 1C0000H to 1CFFFFH 1D0000H to 1DFFFFH 1E0000H to 1EFFFFH 1F0000H to 1FFFFFH
MBM29F016A-70/-90/-12
Table 5 A20 SGA0 SGA1 SGA2 SGA3 SGA4 SGA5 SGA6 SGA7 0 0 0 0 1 1 1 1 Sector Group Addresses A19 0 0 1 1 0 0 1 1 A18 0 1 0 1 0 1 0 1 Sectors SA0 to SA3 SA4 to SA7 SA8 to SA11 SA12 to SA15 SA16 to SA19 SA20 to SA23 SA24 to SA27 SA28 to SA31
Write
Device erasure and programming are accomplished via the command register. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The command register itself does not occupy any addressable memory location. The register is a latch used to store the commands, along with the address and data information needed to execute the command. The command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE, whichever happens first. Standard microprocessor write timings are used. Refer to AC Write Characteristics and the Erase/Programming Waveforms for specific timing parameters.
Sector Group Protection
The MBM29F016A features hardware sector group protection. This feature will disable both program and erase operations in any combination of eight sector groups of memory. Each sector group consists of four adjacent sectors grouped in the following pattern: sectors 0-3, 4-7, 8-11, 12-15, 16-19, 20-23, 24-27, and 28-31 (see Table 5). The sector group protection feature is enabled using programming equipment at the user's site. The device is shipped with all sector groups unprotected. To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest VID = 11.5 V), CE = VIL. The sector addresses (A20, A19, and A18) should be set to the sector to be protected. Tables 4 and 5 define the sector address for each of the thirty two (32) individual sectors, and the sector group address for each of the eight (8) individual group sectors. Programming of the protection circuitry begins on the falling edge of the WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during the WE pulse. See figures 14 and 21 for sector protection waveforms and algorithm. To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9 with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A20, A19, and A18) while (A6, A1, A0) = (0, 1, 0) will produce a logical "1" code at device output DQ0 for a protected sector. Otherwise the device will produce 00H for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6 are DON'T CARES. Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes. It is also possible to determine if a sector group is protected in the system by writing an Autoselect command. Performing a read operation at the address location XX02H, where the higher order addresses (A20, A19, and A18) are the desired sector group address will produce a logical "1" at DQ0 for a protected sector group. See Table 3 for Autoselect codes. 11
MBM29F016A-70/-90/-12
Temporary Sector Group Unprotection
This feature allows temporary unprotection of previously protected sector groups of the MBM29F016A device in order to change data. The Sector Group Unprotection mode is activated by setting the RESET pin to high voltage (12 V). During this mode, formerly protected sector groups can be programmed or erased by selecting the sector group addresses. Once the 12 V is taken away from the RESET pin, all the previously protected sector groups will be protected again. Refer to Figures 14 and 21. Table 6
Bus Write Cycles Req'd
MBM29F016A Command Definitions
Command Sequence
Fifth Bus Sixth Bus First Bus Second Bus Third Bus Fourth Bus Write Cycle Write Cycle Write Cycle Read/Write Write Cycle Write Cycle Cycle Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/Reset* Reset/Read* Autoselect Byte Program Chip Erase Sector Erase
1 3 3 4 6 6
XXXH F0H 555H AAH 555H AAH 555H AAH 555H AAH 555H AAH
-- 2AAH 2AAH 2AAH 2AAH 2AAH
-- 55H 55H 55H 55H 55H
-- 555H 555H 555H 555H 555H
-- F0H 90H A0H 80H 80H
-- RA -- PA
-- RD -- PD
-- -- -- -- 2AAH 2AAH
-- -- -- -- 55H 55H
-- -- -- -- 555H SA
-- -- -- -- 10H 30H
555H AAH 555H AAH
Sector Erase Suspend Sector Erase Resume
Erase can be suspended during sector erase with Addr ("H" or "L"), Data (B0H) Erase can be resumed after suspend with Addr ("H" or "L"), Data (30H)
Notes: 1. Address bits A11 to A20 = X = "H" or "L" for all address commands except or Program Address (PA) and Sector Address (SA). 2. Bus operations are defined in Table 2. 3. RA = Address of the memory location to be read. PA = Address of the memory location to be programmed. Addresses are latched on the falling edge of the WE pulse. SA = Address of the sector to be erased. The combination of A20, A19, A18, A17, and A16 will uniquely select any sector. 4. RD = Data read from location RA during read operation. PD = Data to be programmed at location PA. Data is latched on the rising edge of WE. 5. Read and Byte program functions to non-erasing sectors are allowed in the Erase Suspend mode. 6. The system should generate the following address pattens: 555H or 2AAH to addresses A0 to A10. *: Either of the two reset commands will reset the device.
Command Definitions
Device operations are selected by writing specific address and data sequences into the command register. Writing incorrect address and data values or writing them in the improper sequence will reset the device to the read mode. Table 6 defines the valid register command sequences. Note that the Erase Suspend (B0H) and Erase Resume (30H) commands are valid only while the Sector Erase operation is in progress. Moreover, both Read/Reset commands are functionally equivalent, resetting the device to the read mode. 12
MBM29F016A-70/-90/-12
Read/Reset Command
The read or reset operation is initiated by writing the read/reset command sequence into the command register. Microprocessor read cycles retrieve array data from the memory. The device remains enabled for reads until the command register contents are altered. The device will automatically power-up in the read/reset state. In this case, a command sequence is not required to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no spurious alteration of the memory content occurs during the power transition. Refer to the AC Read Characteristics and Waveforms for the specific timing parameters.
Autoselect Command
Flash memories are intended for use in applications where the local CPU alters memory contents. As such, manufacture and device codes must be accessible while the device resides in the target system. PROM programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high voltage onto the address lines is not generally desirable system design practice. The device contains an autoselect command operation to supplement traditional PROM programming methodology. The operation is initiated by writing the autoselect command sequence into the command register. Following the command write, a read cycle from address XX00H retrieves the manufacture code of 04H. A read cycle from address XX01H returns the device code ADH. (See Table 3). All manufacturer and device codes will exhibit odd parity with the DQ7 defined as the parity bit. Sector state (protection or unprotection) will be informed by address XX02H. Scanning the sector group addresses (A18, A19, A20) while (A6, A1, A0) = (0, 1, 0) will produce a logical "1" at device output DQ0 for a protected sector group. To terminate the operation, it is necessary to write the read/reset command sequence into the register and also to write the Autoselect command during the operation, execute it after writing Read/Reset command sequence.
Byte Programming
The device is programmed on a byte-by-byte basis. Programming is a four bus cycle operation. There are two "unlock" write cycles. These are followed by the program set-up command and data write cycles. Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins programming. Upon executing the Embedded Program Algorithm command sequence, the system is not required to provide further controls or timings. The device will automatically provide adequate internally generated program pulses and verify the programmed cell margin. This automatic programming operation is completed when the data on DQ7 is equivalent to data written to this bit at which time the device returns to the read mode and addresses are no longer latched. (See Table 7, Hardware Sequence Flags.) Therefore, the device requires that a valid address to the device be supplied by the system at this particular instance of time. Data Polling must be performed at the memory location which is being programmed. Any commands written to the chip during this period will be ignored. If a hardware reset occurs during the programming operation, it is impossible to guarantee the data are being written. Programming is allowed in any sequence and across sector boundaries. Beware that a data "0" cannot be programmed back to a "1". Attempting to do so may either hang up the device or result in an apparent success according to the data polling algorithm but a read from reset/read mode will show that the data is still "0". Only erase operations can convert "0"s to "1"s. Figure 16 illustrates the Embedded ProgrammingTM Algorithm using typical command strings and bus operations. 13
MBM29F016A-70/-90/-12
Chip Erase
Chip erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the chip erase command. Chip erase does not require the user to program the device prior to erase. Upon executing the Embedded Erase Algorithm command sequence the device will automatically program and verify the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The automatic erase begins on the rising edge of the last WE pulse in the command sequence and terminates when the data on DQ7 is "1" (see Write Operation Status section) at which time the device returns to read the mode. Figure 17 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
Sector Erase
Sector erase is a six bus cycle operation. There are two "unlock" write cycles. These are followed by writing the "set-up" command. Two more "unlock" write cycles are then followed by the Sector Erase command. The sector address (any address location within the desired sector) is latched on the falling edge of WE, while the command (Data = 30H) is latched on the rising edge of WE. After time-out of 50 s from the rising edge of the last sector erase command, the sector erase operation will begin. Multiple sectors may be erased concurrently by writing the six bus cycle operations on Table 6. This sequence is followed with writes of the Sector Erase command to addresses in other sectors desired to be concurrently erased. The time between writes must be less than 50 s otherwise that command will not be accepted and erasure will start. It is recommended that processor interrupts be disabled during this time to guarantee this condition. The interrupts can be re-enabled after the last Sector Erase command is written. A time-out of 50 s from the rising edge of the last WE will initiate the execution of the Sector Erase command(s). If another falling edge of the WE occurs within the 50 s time-out window the timer is reset. (Monitor DQ3 to determine if the sector erase timer window is still open, see section DQ3, Sector Erase Timer.) Any command other than Sector Erase or Erase Suspend during this time-out period will reset the device to the read mode, ignoring the previous command string. Resetting the device once execution has begun will corrupt the data in that sector. In that case, restart the erase on those sectors and allow them to complete. (Refer to the Write Operation Status section for DQ3, Sector Erase Timer operation.) Loading the sector erase buffer may be done in any sequence and with any number of sectors (0 to 31). Sector erase does not require the user to program the device prior to erase. The device automatically programs all memory locations in the sector(s) to be erased prior to electrical erase. When erasing a sector or sectors the remaining unselected sectors are not affected. The system is not required to provide any controls or timings during these operations. The automatic sector erase begins after the 50 s time out from the rising edge of the WE pulse for the last sector erase command pulse and terminates when the data on DQ7 is "1" (see Write Operation Status section) at which time the device returns to the read mode. Data polling must be performed at an address within any of the sectors being erased. Figure 17 illustrates the Embedded EraseTM Algorithm using typical command strings and bus operations.
Erase Suspend
The Erase Suspend command allows the user to interrupt a Sector Erase operation and then perform data reads from or programs to a sector not being erased. This command is applicable ONLY during a Sector Erase operation which includes the time-out period for sector erase. The Erase Suspend command will be ignored if written during the Chip Erase operation or Embedded Program Algorithm. Writing the Erase Suspend command during 14
MBM29F016A-70/-90/-12
the Sector Erase time-out results in immediate termination of the time-out period and suspension of the erase operation. Any other command written during the Erase Suspend mode will be ignored except the Erase Resume command. Writing the Erase Resume command resumes the erase operation. The addresses are DON'T CARES when writing the Erase Suspend or Erase Resume command. When the Erase Suspend command is written during the Sector Erase operation, the device will take a maximum of 15 s to suspend the erase operation. When the device has entered the erase-suspended mode, the RY/BY output pin and the DQ7 bit will be at logic "1", and DQ6 will stop toggling. The user must use the address of the erasing sector for reading DQ6 and DQ7 to determine if the erase operation has been suspended. Further writes of the Erase Suspend command are ignored. When the erase operation has been suspended, the device defaults to the erase-suspend-read mode. Reading data in this mode is the same as reading from the standard read mode except that the data must be read from sectors that have not been erase-suspended. Successively reading from the erase-suspended sector while the device is in the erase-suspend-read mode will cause DQ2 to toggle. (See the section on DQ2.) After entering the erase-suspend-read mode, the user can program the device by writing the appropriate command sequence for Byte Program. This program mode is known as the erase-suspend-program mode. Again, programming in this mode is the same as programming in the regular Byte Program mode except that the data must be programmed to sectors that are not erase-suspended. Successively reading from the erasesuspended sector while the device is in the erase-suspend-program mode will cause DQ2 to toggle. The end of the erase-suspended program operation is detected by the RY/BY output pin, Data polling of DQ7, or by the Toggle Bit I (DQ6) which is the same as the regular Byte Program operation. Note that DQ7 must be read from the Byte Program address while DQ6 can be read from any address. To resume the operation of Sector Erase, the Resume command (30H) should be written. Any further writes of the Resume command at this point will be ignored. Another Erase Suspend command can be written after the chip has resumed erasing.
15
MBM29F016A-70/-90/-12
Write Operation Status
Table 7 Status Embedded Program Algorithm Embedded Erase Algorithm Erase Suspend Read (Erase Suspended Sector) Erase Suspended Mode Erase Suspend Read (Non-Erase Suspended Sector) Erase Suspend Program (Non-Erase Suspended Sector) Embedded Program Algorithm Exceeded Time Limits Embedded Erase Algorithm Erase Suspended Mode Erase Suspend Program (Non-Erase Suspended Sector) Hardware Sequence Flags DQ7 DQ7 0 1 Data DQ7 DQ7 0 DQ7 DQ6 Toggle Toggle 1 Data Toggle (Note 2) Toggle Toggle Toggle DQ5 0 0 0 Data 0 1 1 1 DQ3 0 1 0 Data 0 0 1 0 DQ2 1 Toggle Toggle (Note 1) Data 1 (Note 3) 1 N/A N/A
In Progress
Notes: 1. Performing successive read operations from the erase-suspended sector will cause DQ2 to toggle. 2. Performing successive read operations from any address will cause DQ6 to toggle. 3. Reading the byte address being programmed while in the erase-suspend program mode will indicate logic "1" at the DQ2 bit. However, successive reads from the erase-suspended sector will cause DQ2 to toggle.
DQ7
Data Polling The MBM29F016A device features Data Polling as a method to indicate to the host that the embedded algorithms are in progress or completed. During the Embedded Program Algorithm, an attempt to read the device will produce the complement of the data last written to DQ7. Upon completion of the Embedded Program Algorithm, an attempt to read the device will produce the true data last written to DQ7. During the Embedded EraseTM Algorithm, an attempt to read the device will produce a "0" at the DQ7 output. Upon completion of the Embedded Erase Algorithm an attempt to read the device will produce a "1" at the DQ7 output. The flowchart for Data Polling (DQ7) is shown in Figure 18. Data polling will also flag the entry into Erase Suspend. DQ7 will switch "0" to "1" at the start of the Erase Suspend mode. Please note that the address of an erasing sector must be applied in order to observe DQ7 in the Erase Suspend Mode. During Program in Erase Suspend, Data polling will perform the same as in regular program execution outside of the suspend mode. For chip erase, the Data Polling is valid after the rising edge of the sixth WE pulse in the six write pulse sequence. For sector erase, the Data Polling is valid after the last rising edge of the sector erase WE pulse. Data Polling must be performed at sector address within any of the sectors being erased and not a sector that is within a protected sector group. Otherwise, the status may not be valid. Just prior to the completion of Embedded Algorithm operation DQ7 may change asynchronously while the output enable (OE) is asserted low. This means that the device is driving status information on DQ7 at one instant of time and then that byte's valid data at the next instant of time. Depending on when the system samples the DQ7 16
MBM29F016A-70/-90/-12
output, it may read the status or valid data. Even if the device has completed the Embedded Algorithm operations and DQ7 has a valid data, the data outputs on DQ0 to DQ6 may be still invalid. The valid data on DQ0 to DQ7 will be read on the successive read attempts. The Data Polling feature is only active during the Embedded Programming Algorithm, Embedded Erase Algorithm, Erase Suspend, erase-suspend-program mode, or sector erase time-out. (See Table 7.) See Figure 9 for the Data Polling timing specifications and diagrams.
DQ6
Toggle Bit I The MBM29F016A also features the "Toggle Bit I" as a method to indicate to the host system that the embedded algorithms are in progress or completed. During an Embedded Program or Erase Algorithm cycle, successive attempts to read (OE toggling) data from the device at any address will result in DQ6 toggling between one and zero. Once the Embedded Program or Erase Algorithm cycle is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During programming, the Toggle Bit I is valid after the rising edge of the fourth WE pulse in the four write pulse sequence. For chip erase, and sector erase the Toggle Bit I is valid after the rising edge of the sixth WE pulse in the six write pulse sequence. For Sector Erase, the Toggle Bit I is valid after the last rising edge of the sector erase WE pulse. The Toggle Bit I is active during the sector erase time out. In programming, if the sector being written to is protected, the Toggle Bit I will toggle for about 2 s and then stop toggling without the data having changed. In erase, the device will erase all the selected sectors except for the ones that are protected. If all selected sectors are protected, the chip will toggle the Toggle Bit I for about 100 s and then drop back into read mode, having changed none of the data. Either CE or OE toggling will cause the DQ6 to toggle. In addition, an Erase Suspend/Resume command will cause DQ6 to toggle. See Figure 10 for the Toggle Bit I timing specifications and diagrams.
DQ5
Exceeded Timing Limits DQ5 will indicate if the program or erase time has exceeded the specified limits (internal pulse count). Under these conditions DQ5 will produce a "1". This is a failure condition which indicates that the program or erase cycle was not successfully completed. Data Polling DQ7, DQ6 is the only operating function of the device under this condition. The CE circuit will partially power down the device under these conditions (to approximately 2 mA). The OE and WE pins will control the output disable functions as described in Table 2. The DQ5 failure condition may also appear if a user tries to program a 1 to a location that is previously programmed to 0. In this case the device locks out and never completes the Embedded Algorithm operation. Hence, the system never reads a valid data on DQ7 bit and DQ6 never stops toggling. Once the device has exceeded timing limits, the DQ5 bit will indicate a "1." Please note that this is not a device failure condition since the device was incorrectly used. If this occurs, reset the device.
DQ3
Sector Erase Timer After the completion of the initial sector erase command sequence the sector erase time-out will begin. DQ3 will remain low until the time-out is complete. Data Polling and Toggle Bit I are valid after the initial sector erase command sequence. If Data Polling or the Toggle Bit I indicates the device has been written with a valid erase command, DQ3 may be used to determine if the sector erase timer window is still open. If DQ3 is high ("1") the internally controlled 17
MBM29F016A-70/-90/-12
erase cycle has begun; attempts to write subsequent commands (other than Erase Suspend) to the device will be ignored until the erase operation is completed as indicated by Data Polling or Toggle Bit I. If DQ3 is low ("0"), the device will accept additional sector erase commands. To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3 were high on the second status check, the command may not have been accepted. Refer to Table 7: Hardware Sequence Flags.
DQ2
Toggle Bit II This toggle bit II, along with DQ6, can be used to determine whether the device is in the Embedded EraseTM Algorithm or in Erase Suspend. Successive reads from the erasing sector will cause DQ2 to toggle during the Embedded EraseTM Algorithm. If the device is in the erase-suspended-read mode, successive reads from the erase-suspended sector will cause DQ2 to toggle. When the device is in the erase-suspended-program mode, successive reads from the byte address of the non-erase suspended sector will indicate a logic "1" at the DQ2 bit. Mode Program Erase Erase Suspend Read (1) (Erase-Suspended Sector) Erase Suspend Program DQ7 DQ7 0 1 DQ7 (2) DQ6 toggles toggles 1 toggles DQ2 1 toggles toggles 1 (2)
Notes: 1. These status flags apply when outputs are read from a sector that has been erase-suspended. 2. These status flags apply when outputs are read from the byte address of the non-erase suspended sector. DQ6 is different from DQ2 in that DQ6 toggles only when the standard program or Erase, or Erase Suspend Program operation is in progress. The behavior of these two status bits, along with that of DQ7, is summarized as follows: For example, DQ2 and DQ6 can be used together to determine the erase-suspend-read mode (DQ2 toggles while DQ6 does not). See also Table 7 and Figure 15. Furthermore, DQ2 can also be used to determine which sector is being erased. When the device is in the erase mode, DQ2 toggles if this bit is read from the erasing sector.
RY/BY
Ready/Busy The MBM29F016A provides a RY/BY open-drain output pin as a way to indicate to the host system that the Embedded Algorithms are either in progress or has been completed. If the output is low, the device is busy with either a program or erase operation. If the output is high, the device is ready to accept any read/write or erase operation. When the RY/BY pin is low, the device will not accept any additional program or erase commands with the exception of the Erase Suspend command. If the MBM29F016A is placed in an Erase Suspend mode, the RY/BY output will be high, by means of connecting with a pull-up resistor to VCC. During programming, the RY/BY pin is driven low after the rising edge of the fourth WE pulse. During an erase operation, the RY/BY pin is driven low after the rising edge of the sixth WE pulse. The RY/BY pin will indicate a busy condition during RESET pulse. Refer to Figure 11 for a detailed timing diagram. The RY/BY pin is pulled high in standby mode. 18
MBM29F016A-70/-90/-12
Since this is an open-drain output, several RY/BY pins can be tied together in parallel with a pull-up resistor to VCC.
RESET
Hardware Reset The MBM29F016A device may be reset by driving the RESET pin to VIL. The RESET pin must be kept low (VIL) for at least 500 ns. Any operation in progress will be terminated and the internal state machine will be reset to the read mode 20 s after the RESET pin is driven low. If a hardware reset occurs during a program operation, the data at that particular location will be indeterminate. When the RESET pin is low and the internal reset is complete, the device goes to standby mode and cannot be accessed. Also, note that all the data output pins are tri-stated for the duration of the RESET pulse. Once the RESET pin is taken high, the device requires tRH of wake up time until outputs are valid for read access. The RESET pin may be tied to the system reset input. Therefore, if a system reset occurs during the Embedded Program or Erase Algorithm, the device will be automatically reset to read mode and this will enable the system's microprocessor to read the boot-up firmware from the Flash memory.
Data Protection
The MBM29F016A is designed to offer protection against accidental erasure or programming caused by spurious system level signals that may exist during power transitions. During power up the device automatically resets the internal state machine in the Read mode. Also, with its control register architecture, alteration of the memory contents only occurs after successful completions of specific multi-bus cycle command sequences. The device also incorporates several features to prevent inadvertent write cycles resulting from VCC power-up and power-down transitions or system noise.
Low VCC Write Inhibit
To avoid initiation of a write cycle during VCC power-up and power-down, a write cycle is locked out for VCC less than 3.2 V (typically 3.7 V). If VCC < VLKO, the command register is disabled and all internal program/erase circuits are disabled. Under this condition the device will reset to the read mode. Subsequent writes will be ignored until the VCC level is greater than VLKO. It is the users responsibility to ensure that the control pins are logically correct to prevent unintentional writes when VCC is above 3.2 V.
Write Pulse "Glitch" Protection
Noise pulses of less than 5 ns (typical) on OE, CE, or WE will not initiate a write cycle.
Logical Inhibit
Writing is inhibited by holding any one of OE = VIL, CE = VIH or WE = VIH. To initiate a write cycle CE and WE must be a logical zero while OE is a logical one.
Power-Up Write Inhibit
Power-up of the device with WE = CE = VIL and OE = VIH will not accept commands on the rising edge of WE. The internal state machine is automatically reset to the read mode on power-up.
19
MBM29F016A-70/-90/-12
s ABSOLUTE MAXIMUM RATINGS
Storage Temperature ........................................................................................-55C to +125C Ambient Temperature with Power Applied ........................................................-40C to +85C Voltage with Respect to Ground All pins except A9, OE, and RESET (Note 1).-2.0 V to +7.0 V VCC (Note 1) ......................................................................................................-2.0 V to +7.0 V A9, OE, and RESET (Note 2) ............................................................................-2.0 V to +13.5 V Notes: 1. Minimum DC voltage on input or I/O pins is -0.5 V. During voltage transitions, inputs may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC voltage on output and I/O pins is VCC +0.5 V. During voltage transitions, outputs may positive overshoot to VCC +2.0 V for periods up to 20 ns. 2. Minimum DC input voltage on A9, OE, and RESET pins are -0.5 V. During voltage transitions, A9, OE, and RESET pins may negative overshoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC input voltage on A9, OE, and RESET are +13.0 V which may overshoot to 14.0 V for periods up to 20 ns. Voltage difference between input voltage and power supply. (VIN - VCC) do not exceed 9 V. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING RANGES
Ambient Temperature (TA) ................................................................................ -40C to +85C VCC Supply Voltages MBM29F016A-70............................................................................................ +4.75 V to +5.25 V MBM29F016A-90/-12...................................................................................... +4.50 V to +5.50 V Operating ranges define those limits between which the functionality of the device is guaranteed. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.
20
MBM29F016A-70/-90/-12
s MAXIMUM OVERSHOOT
+0.8 V -0.5 V -2.0 V
20 ns
20 ns
20 ns
Figure 1
Maximum Negative Overshoot Waveform
20 ns
VCC +2.0 V VCC +0.5 V +2.0 V
20 ns 20 ns
Figure 2
Maximum Positive Overshoot Waveform 1
20 ns
+14.0 V +13.0 V VCC +0.5 V
20 ns 20 ns
* : This waveform is applied for A9, OE, and RESET.
Figure 3
Maximum Positive Overshoot Waveform 2
21
MBM29F016A-70/-90/-12
s DC CHARACTERISTICS
Parameter Symbol ILI ILO ILIT ICC1 ICC2 Parameter Description Input Leakage Current Output Leakage Current A9, OE, RESET Inputs Leakage Current VCC Active Current (Note 1) VCC Active Current (Note 2) Test Conditions VIN = VSS to VCC, VCC = VCC Max. VOUT = VSS to VCC, VCC = VCC Max. VCC = VCC Max. A9, OE, RESET = 12.5 V CE = VIL, OE = VIH CE = VIL, OE = VIH VCC = VCC Max., CE = VIH RESET = VIH ICC3 VCC Current (Standby) VCC = VCC Max., CE = VCC 0.3 V, RESET = VCC 0.3 V VCC = VCC Max. RESET = VIL ICC4 VCC Current (Standby, Reset) VCC = VCC Max. RESET = VSS 0.3 V VIL VIH VID VOL VOH1 Output High Voltage Level VOH2 VLKO Low VCC Lock-Out Voltage Input Low Level Input High Level Voltage for Autoselect and Sector Protection (A9, OE, RESET) (Note 3, 4) Output Low Voltage Level -- -- -- IOL = 12.0 mA, VCC = VCC Min. IOH = -2.5 mA, VCC = VCC Min. IOH = -100 A -- -- -0.5 2.0 11.5 -- 2.4 VCC-0.4 3.2 5 0.8 VCC+0.5 12.5 0.45 -- -- 4.2 A V V V V V V V -- -- 5 1 A mA Min. -- -- -- -- -- -- Max. 1.0 1.0 50 40 45 1 Unit A A A mA mA mA
Notes: 1. The ICC current listed includes both the DC operating current and the frequency dependent component (at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH. 2. ICC active while Embedded Algorithm (program or erase) is in progress. 3. Applicable to sector protection function. 4. (VID - VCC) do not exceed 9 V.
22
MBM29F016A-70/-90/-12
s AC CHARACTERISTICS
* Read Only Operations Characteristics Parameter Symbols JEDEC Standard tAVAV tAVQV tELQV tGLQV tEHQZ tGHQZ tAXQX -- tRC tACC tCE tOE tDF tDF tOH tREADY Read Cycle Time Address to Output Delay Chip Enable to Output Delay Output Enable to Output Delay Chip Enable to Output HIGH-Z Output Enable to Output HIGH-Z Output Hold Time From Addresses, CE or OE, whichever occurs first RESET Pin Low to Read Mode -- CE = VIL OE = VIL OE = VIL -- -- -- -- -- Min. Max. Max. Max. Max. Max. Min. Max. -70 -90 -12 (Note1) (Note2) (Note2) Unit 70 70 70 40 20 20 0 20 90 90 90 40 20 20 0 20 120 120 120 50 30 30 0 20 ns ns ns ns ns ns ns s
Description
Test Setup
Note: 1. Test Conditions: Output Load: 1 TTL gate and 30 pF Input rise and fall times: 5 ns Input pulse levels: 0.0 V to 3.0 V Timing measurement reference level Input: 1.5 V Output: 1.5 V
Note: 2. Test Conditions: Output Load: 1 TTL gate and 100 pF Input rise and fall times: 5 ns Input pulse levels: 0.45 V to 2.4 V Timing measurement reference level Input: 0.8 V and 2.0 V Output: 0.8 V and 2.0 V
5.0 V IN3064 or Equivalent Device Under Test 6.2 k CL Diodes = IN3064 or Equivalent
2.7 k
Note: 1. CL = 30 pF including jig capacitance 2. CL = 100 pF including jig capacitance Figure 4 Test Conditions
23
MBM29F016A-70/-90/-12
* Write/Erase/Program Operations Parameter Symbols JEDEC tAVAV tAVWL tWLAX tDVWH tWHDX -- -- tGHWL tGHEL tELWL tWLEL tWHEH tEHWH tWLWH tELEH tWHWL tEHEL tWHWH1 tWHWH2 -- -- -- -- -- -- Standard tWC tAS tAH tDS tDH tOES tOEH tGHWL tGHEL tCS tWS tCH tWH tWP tCP tWPH tCPH tWHWH1 tWHWH2 tVCS tVLHT tWPP tOESP tCSP tRB Write Cycle Time Address Setup Time Address Hold Time Data Setup Time Data Hold Time Output Enable Setup Time Output Read Enable Hold Toggle Bit I and Data Polling Time Read Recover Time Before Write Read Recover Time Before Write CE Setup Time WE Setup Time CE Hold Time WE Hold Time Write Pulse Width Write Pulse Width Write Pulse Width High Write Pulse Width High Byte Programming Operation Sector Erase Operation (Note 1) VCC Setup Time Voltage Transition Time (Note 2) Write Pulse Width (Note 2) OE Setup Time to WE Active (Note 2) CE Setup Time to WE Active (Note 2) Recover Time from RY/BY Description Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Min. Typ. Typ. Max. Min. Min. Min. Min. Min. Min. -70 70 0 45 30 0 0 0 10 0 0 0 0 0 0 35 35 20 20 8 1 8 50 4 100 4 4 0 MBM29F016A -90 90 0 45 45 0 0 0 10 0 0 0 0 0 0 45 45 20 20 8 1 8 50 4 100 4 4 0 -12 120 0 50 50 0 0 0 10 0 0 0 0 0 0 50 50 20 20 8 1 8 50 4 100 4 4 0 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns s sec sec s s s s s ns
(Continued)
24
MBM29F016A-70/-90/-12
(Continued)
Parameter Symbols JEDEC -- -- -- -- Standard tRP tRH tBUSY tEOE RESET Pulse Width RESET Hold Time Before Read Program/Erase Valid to RY/BY Delay Description Min. Min. Max. Max. -70 500 50 70 40 MBM29F016A -90 500 50 90 40 -12 500 50 120 50 Unit ns ns ns ns
Notes: 1. This does not include the preprogramming time. 2. This timing is for Sector Protection operation.
25
MBM29F016A-70/-90/-12
s SWITCHING WAVEFORMS
* Key to Switching Waveforms
WAVEFORM INPUTS Must Be Steady May Change from H to L May Change from L to H "H" or "L" Any Change Permitted Does Not Apply OUTPUTS Will Be Steady Will Be Changing from H to L Will Be Changing from L to H Changing, State Unknown Center Line is HighImpedance "Off" State
tRC
Addresses
tACC
Addresses Stable
CE
tOE tDF
OE
tOEH
WE
tCE tOH
Outputs
High-Z
Output Valid
High-Z
Figure 5
AC Waveforms for Read Operations
26
MBM29F016A-70/-90/-12
3rd Bus Cycle Addresses
555H tWC tAS tCH PA tAH
Data Polling
PA tRC
CE
tGHWL
OE
tWP
tWHWH1
WE
tCS tWPH tDF tOE PD DQ7 DOUT DOUT tOH
tDH A0H
Data
tDS
5.0 V
tCE
Notes: 1. PA is address of the memory location to be programmed. 2. PD is data to be programmed at byte address. 3. DQ7 is the output of the complement of the data written to the device. 4. DOUT is the output of the data written to the device. 5. Figure indicates last two bus cycles of four bus cycle sequence.
Figure 6
AC Waveforms for Alternate WE Controlled Program Operations
27
MBM29F016A-70/-90/-12
3rd Bus Cycle
Data Polling PA tAH tAS PA
Addresses
555H tWC tWH
WE
tGHEL
OE
tCP
tWHWH1
CE
tWS tCPH
tDH
Data
A0H tDS
PD
DQ7
DOUT
5.0 V
Notes: 1. PA is address of the memory location to be programmed. 2. PD is data to be programmed at byte address. 3. DQ7 is the output of the complement of the data written to the device. 4. DOUT is the output of the data written to the device. 5. Figure indicates last two bus cycles of four bus cycle sequence.
Figure 7
AC Waveforms for Alternate CE Controlled Program Operations
28
MBM29F016A-70/-90/-12
tAH
Addresses
555H
2AAH tAS
555H
555H
2AAH
SA*
CE
tGHWL
OE
tWP
WE
tCS tWPH tDH
Data
tDS
AAH
55H
80H
AAH
55H
10H/30H
VCC
tVCS
* : SA is the sector address for Sector Erase. Addresses = 555H for Chip Erase.
Figure 8
AC Waveforms Chip/Sector Erase Operations
29
MBM29F016A-70/-90/-12
CE
tCH tDF tOE
OE
tOEH
WE
tCE
*
DQ7
Data
DQ7
DQ7 = Valid Data tEOE
High-Z
tWHWH1 or 2
DQ0 to DQ6
Data
DQ0 to DQ6 = Output Flug
DQ0 to DQ7 Valid Data
High-Z
* : DQ7 = Valid Data (The device has completed the Embedded operation.) Figure 9 AC Waveforms for Data Polling During Embedded Algorithm Operations
CE
tOEH
WE
tOES
OE
*
DQ6
Data
DQ6 = Toggle
DQ6 = Toggle tOE
DQ6 = Stop Toggling
DQ0 to DQ7 Valid
* : DQ6 stops toggling (The device has completed the Embedded operation.) Figure 10 AC Waveforms for Toggle Bit I during Embedded Algorithm Operations
30
MBM29F016A-70/-90/-12
CE
The rising edge of the last WE signal
WE
Entire programming or erase operations
RY/BY
tBUSY
Figure 11
RY/BY Timing Diagram During Program/Erase Operations
WE
RESET
tRP tREADY tRB
RY/BY
Figure 12
RESET, RY/BY Timing Diagram
31
MBM29F016A-70/-90/-12
A 20, A 19, A 18
SGAX
SGAY
A0
A1
A6 12V 5V A9 12V 5V OE tVLHT tWPP WE tOESP tCSP tVLHT tVLHT tVLHT
CE
Data tVCS VCC tOE
01H
SGAX = Sector Group Address for initial sector SGAY = Sector Group Address for next sector
Figure 13
AC Waveforms for Sector Group Protection Timing Diagram
32
MBM29F016A-70/-90/-12
VCC tVCS VID 5V RESET CE
tVIDR tVLHT
5V
WE
tVLHT RY/BY
Program or Erase Command Sequence
tVLHT
Unprotection period
Figure 14
Temporary Sector Group Unprotection Timing Diagram
Enter Embedded Erasing WE
Erase Suspend Erase
Enter Erase Suspend Program Erase Suspend Program
Erase Resume Erase Suspend Read Erase Erase Complete
Erase Suspend Read
DQ6
DQ2 Toggle DQ2 and DQ6 with OE
Note: DQ2 is read from the erase-suspended sector. Figure 15 DQ2 vs. DQ6
33
MBM29F016A-70/-90/-12
EMBEDDED ALGORITHMS
Start
Write Program Command Sequence (See Below)
Data Polling Device
Increment Address
No
Last Address ? Yes
Programming Completed
Program Command Sequence (Address/Command):
555H/AAH
2AAH/55H
555H/A0H
Program Address/Program Data
Figure 16
Embedded ProgramTM Algorithm
34
MBM29F016A-70/-90/-12
Start
Write Erase Command Sequece (See Below) Data Polling or Toggle Bit I Successfully Completed
Erasure Completed
Chip Erase Command Sequence (Address/Command): 555H/AAH
Individual Sector/Multiple Sector Erase Command Sequence (Address/Command): 555H/AAH
2AAH/55H
2AAH/55H
555H/80H
555H/80H
555H/AAH
555H/AAH
2AAH/55H
2AAH/55H
555H/10H
Sector Address/30H
Sector Address/30H
Additional sector erase commands are optional.
Sector Address/30H
Note: To insure the command has been accepted, the system software should check the status of DQ3 prior to and following each subsequent sector erase command. If DQ3 were high on the second status check, the command may not have been accepted.
Figure 17
Embedded EraseTM Algorithm
35
MBM29F016A-70/-90/-12
Start
Read Byte (DQ0 to DQ7) Addr. = VA
DQ7 = Data? No No DQ5 = 1? Yes Read Byte (DQ0 to DQ7) Addr. = VA
Yes
VA = Address for programming = Any of the sector addresses within the sector being erased during sector erase or multiple erases operation. = Any of the sector group addresses within the sector not being protected during sector erase or multiple sector erases operation.
DQ7 = Data? No Fail
Yes
Pass
Note: DQ7 is rechecked even if DQ5 = "1" because DQ7 may change simultaneously with DQ5.
Figure 18
Data Polling Algorithm
36
MBM29F016A-70/-90/-12
Start
Read Byte (DQ0 to DQ7) Addr. = "H" or "L" No DQ6 = Toggle ? Yes No DQ5 = 1 ? Yes Read Byte (DQ0 to DQ7) Addr. = "H" or "L"
DQ6 = Toggle ? Yes Fail
No
Pass
Note: DQ6 is rechecked even if DQ5 = "1" because DQ6 may stop toggling at the same time as DQ5 changing to "1".
Figure 19
Toggle Bit I Algorithm
37
MBM29F016A-70/-90/-12
Start
Setup Sector Group Addr. (A20, A19, A18)
PLSCNT = 1
OE = VID, A9 = VID, CE = VIL, RESET = VIH
Increment PLSCNT
Activate WE Pulse
Time out 100 s
WE = VIH, CE = OE = VIL, (A9 should remain VID)
Read from Sector Group Addr. (A20, A19, A18) A1 = 1, A0 = A6 = 0 No No PLSCNT = 25? Yes Remove VID from A9 Write Reset Command Data = 01H? Yes Yes Protect Another Sector Group? No Device Failed Remove VID from A9 Write Reset Command
Sector Protection Completed
Figure 20
Sector Group Protection Algorithm
38
MBM29F016A-70/-90/-12
Start
RESET = VID (Note 1)
Perform Erase or Program Operations
RESET = VIH
Temporary Sector Group Unprotection Completed (Note 2)
Notes: 1. All Protected sector groups unprotected. 2. All previously protected sector groups are protected once again. Figure 21 Temporary Sector Group Unprotection Algorithm
39
MBM29F016A-70/-90/-12
s ERASE AND PROGRAMMING PERFORMANCE
Limits Parameter Min. Sector Erase Time Byte Programming Time Chip Programming Time Erase/Program Cycle -- -- -- 100,000 Typ. 1 8 16.8 -- Max. 8 150 40 -- sec s sec cycles Excludes 00H programming prior to erasure Excludes system-level overhead Excludes system-level overhead Unit Comments
s TSOP(I) PIN CAPACITANCE
Parameter Symbol CIN COUT CIN2 Parameter Description Input Capacitance Output Capacitance Control Pin Capacitance Test Setup VIN = 0 VOUT = 0 VIN = 0 Typ. 8 8 9 Max. 10 10 10 Unit pF pF pF
Note: Test conditions TA = 25C, f = 1.0 MHz
40
MBM29F016A-70/-90/-12
s PACKAGE DIMENSIONS
48-pin plastic TSOP(I) (FPT-48P-M19)
*: Resin Protrusion. (Each Side:0.15(.006)MAX)
LEAD No.
1 48
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
20.000.20 (.787.008) * 18.400.20 (.724.008)
* 12.000.20 (.472.008) 11.50REF (.460)
(Mounting height)
1.10 -0.05 +.004 .043 -.002
+0.10
0.10(.004)
0.50(.0197) TYP 0.150.05 (.006.002) 0.200.10 (.008.004)
0.05(0.02)MIN STAND OFF 0.10(.004)
M
19.000.20 (.748.008)
0.500.10 (.020.004)
C
1996 FUJITSU LIMITED F48029S-2C-2
Dimensions in mm(inches)
(Continued)
41
MBM29F016A-70/-90/-12
(Continued)
48-pin plastic TSOP(I) (FPT-48P-M20)
*: Resin Protrusion. (Each Side:0.15(.006)MAX)
LEAD No.
1 48
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
19.000.20 (.748.008)
0.500.10 (.020.004) 0.150.10 (.006.002) 0.200.10 (.008.004) 0.10(.004)
M
0.10(.004)
0.50(.0197) TYP
0.05(0.02)MIN STAND OFF
* 18.400.20 (.724.008) 20.000.20 (.787.008)
11.50(.460)REF * 12.000.20(.472.008)
1.10 -0.05 +.004 .043 -.002
(Mounting height)
+0.10
C
1996 FUJITSU LIMITED F48030S-2C-2
Dimensions in mm(inches)
42
MBM29F016A-70/-90/-12
FUJITSU LIMITED
For further information please contact:
Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices KAWASAKI PLANT, 4-1-1, Kamikodanaka Nakahara-ku, Kawasaki-shi Kanagawa 211-8588, Japan Tel: 81(44) 754-3763 Fax: 81(44) 754-3329
All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipment, industrial, communications, and measurement equipment, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have an inhereut chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Law of Japan, the prior authorization by Japanese government will be required for export of those products from Japan.
http://www.fujitsu.co.jp/
North and South America FUJITSU MICROELECTRONICS, INC. Semiconductor Division 3545 North First Street San Jose, CA 95134-1804, USA Tel: (408) 922-9000 Fax: (408) 922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: (800) 866-8608 Fax: (408) 922-9179
http://www.fujitsumicro.com/
Europe FUJITSU MIKROELEKTRONIK GmbH Am Siebenstein 6-10 D-63303 Dreieich-Buchschlag Germany Tel: (06103) 690-0 Fax: (06103) 690-122
http://www.fujitsu-ede.com/
Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE LTD #05-08, 151 Lorong Chuan New Tech Park Singapore 556741 Tel: (65) 281-0770 Fax: (65) 281-0220
http://www.fmap.com.sg/
F9903 (c) FUJITSU LIMITED Printed in Japan
43


▲Up To Search▲   

 
Price & Availability of MBM29F016A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X